Toll Free: 800-345-4364  |  sales@aircompressorworks.com
Air Compressor Works Inc.
PRODUCTSKaeser CompressorsReciprocating / Piston
Compressors
Vacuum, Medical Air &
Dental Systems
Portable Air
Compressors
Compressed Air
Treatment & Breathing
Air Systems
Nitrogen Systems &
Generators
Heat Transfer & Chilled
Water Products
Tanks & PipingElectric MotorsLubricantParts & AccessoriesServicesIndustry LinksHelpful Information & LinksEmployment OpportunitiesUsed & Rebuilt Equipment24 Hour Emergency Service AvailableCertificationsState Certified Mechanical Contractor - License #CMC1249580

Florida Healthcare
Engineering Association

Kaeser Factory Certified

Compressed Air Challenge Certification of Completion
View RFQs  | Shipping 
 | Tax 
 | Terms
 Request for Quote 0 Items
All Categories > Vacuum, Medical Air & Dental Systems > Dew Point & CO Monitors > Item # item-2439  
Request Quote

Item # item-2439, GMA 4100-DP


    Download PDF Download PDF   
    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

GMA 4100-DP Control Panel Dew Point
  • Reading of dew point values on a 3-digit display
  • Menu display
  • 3 variably adjustable alarm thresholds
  • Peak value memory
  • Adjustable relay functions: NC / NO contact, open-circuit / closed circuit
  • Alarm hystereses prevents "flickering" of relays
  • 4 - 20 mA analog output signal





Specifications

Climate Conditions For Operation

32 to 131°F (0 to +55°C), 0 to 99 % r.h.

Output Signals Analog Outputs For Measured Value

4 to 20 mA, Maximum Load 300

Relays Maximum Switch Voltage

250 VAC 50/60 HZ
250 VDC

Max. Switch Current

4 A AC/DC
Relay outputs and mains entry are operation insulated

Max. Switch Performance

1000 VAC

Protective Separation

By safety transformer

Protective Insulation

As per EN 61010 up to over voltage category III and soiling degree 2

Dew Point Temperature Range

-60 to +60 ºC

Power Source

24 VDC wall pack

Dimensions (W x D x H)

12 x 12 x 3.5 in
304.8 x 304.8 x 88.9
mm

Alarms

3 adjustable alarm points 1 fault alarm

Alarm Functions

Alarm thresholds completely adjustable (above zero only)
Delay-time o to 2 minutes

Hysteresis adjustable

Relay Outputs

4 voltage-free relays for alarm and fault
Load: 250 VAC, 4 A

Normally closed contact (NC)

Normally open contact (NO)

Display

1 LED Green - operational status
1 LED Yellow - Fault

3 LEDs Red - Alarm

3-digit LED display

Function Keys

Push-button operation for alarm points, function test, and relay test